Request a Quote
EICR & Electrical Safety Testing

EICR remedial work: what landlords must fix, by when and who can do it

Published · 7 min read · By DA Electrical London
On this page
  1. Which EICR codes need remedial work?
  2. The 28-day clock starts on the inspection day
  3. Can a different electrician do the remedial work?
  4. Common remedial items and what they cost to put right
  5. FI codes and the change due on 30 November 2026
  6. What happens if remedial work isn't done in time?
  7. Homeowners have no deadline, but C1 still means today

The short version

  • Only C1 and C2 items need remedial work; a C3 is a recommendation landlords don't have to follow.
  • A landlord's 28 days run from the inspection date, not the day the report arrives.
  • Any qualified electrician can do the work; it needn't be the one who wrote the report.
  • Tenants and the council get written proof within 28 days of the work being finished.
  • Treat an FI as a 28-day job until the draft amendment due on 30 November 2026 is made.

EICR remedial work means fixing every C1 and C2 fault on the report, which a landlord in England must have done within 28 days of the inspection. A qualified person does the work, the report can set a shorter deadline, and the tenants and the council then get written proof.

Which EICR codes need remedial work?

Only two codes on an EICR call for repairs: C1 and C2. Since 15 October 2026, when Amendment 4 became the only current wiring regulations, they're also the only codes that fail a report.

CodeWhat it meansLandlord in EnglandHomeowner
C1Danger present: immediate remedial actionFix within 28 days, or the shorter period on the reportMake it safe now
C2Potentially dangerous: urgent remedial actionFix within 28 days, or the shorter period on the reportFix it urgently
FIFurther investigation advisedInvestigate within 28 days (see the 30 November change below)Have it looked at
C3Improvement recommendedNo duty to actYour choice

The government's guidance for landlords is plain about the lowest code:

"The C3 code does not indicate remedial work is required, but only that improvement is recommended." GOV.UK, Electrical safety standards guidance, 1 November 2025

What each code means in detail is in our guide to what an EICR report and its codes mean. If your report lists items that need work, our EICR team can price the remedial work from the report.

The 28-day clock starts on the inspection day

Regulation 3 of the 2020 regulations counts the remedial deadline from the inspection and test, not from the day the report arrives. A report that reaches you a week after the visit leaves three weeks, not four. Here is how the dates fall from a single inspection:

  1. On day 0 the electrician inspects and tests the installation.
  2. By day 28 each existing tenant has a copy of the report.
  3. By day 28, or sooner if the report says, the remedial and investigative work is finished.
  4. If the council asks in writing, it gets a copy of the report within 7 days.
  5. Within 28 days of finishing the work, written confirmation and the report go to each tenant and the council.
The landlord's two 28-day deadlines after an EICR: one from the inspection, one from finishing the work Day 0 Inspection Day 28 at the latest Report to tenants Remedial work finished 28 days after the work Written proof to tenants and the council Counted from the inspection Counted from finishing the work
The remedial deadline runs from the inspection day, not the day the report arrives; the proof deadline runs from when the work is finished.

What counts as proof the work is done

The proof is written confirmation from the qualified person who did the work. The guidance lists what's acceptable: a satisfactory EICR, an Electrical Installation Certificate, or a Minor Electrical Installation Works Certificate. When we do the remedial work, we sign that confirmation for our own work.

Can a different electrician do the remedial work?

Yes. The regulations ask for the work to be carried out by "a qualified person", meaning someone competent to do the inspection and testing. They don't say it has to be the electrician who wrote the report, so you can get a second price. Send us the report and we'll price the remedial work from it.

Whoever does it signs the written confirmation for their own work. On reports we write, we quote remedial work separately once the report is written. We're NICEIC approved.

Common remedial items and what they cost to put right

Electrical Safety First's guide to EICR codes lists the findings inspectors code as C2. These are some of the ones a rented home turns up, with the usual fix and our guide price for it, including VAT:

C2 findingUsual fixOur guide price
No RCD for sockets likely to feed equipment used outdoorsRCD protection added, sometimes with a new consumer unitnew consumer unit from £400
A loose connection showing signs of overheatingConnection remade, damaged socket or switch replacedfrom £80
Signs of excessive heat, such as charringCause traced (fault finding from £100); the repair is priced afterfrom £100 for the tracing
Incorrect polarity at a socket, switch or lightReconnected, or the accessory replacedfrom £80

A circuit that can't be made safe is rewired instead, and our guide price for a partial rewire is from £2,000. These are guide prices, not a quote. We price your report once we've read the observations. A board change follows the testing steps in our guide to what a consumer unit replacement costs.

FI codes and the change due on 30 November 2026

FI used to fail a report. Under Amendment 4, NICEIC explains, an FI no longer makes the installation unsatisfactory, and its wording dropped "without delay". The law for landlords hasn't caught up yet, so the wiring standard and the landlord regulations currently treat FI differently.

What the draft amendment would change

The 2020 regulations still require further investigative work within 28 days, and the current guidance says the same. A draft amendment would remove that duty from 30 November 2026, and update the standard to BS 7671:2018+A4:2026. On 16 November 2026 it was still marked as not yet made.

Even if it's made, the draft says the change won't apply to inspections completed before 30 November 2026. An FI on an earlier report stays a 28-day job. On reports we write, we quote any FI investigation separately once the report is written.

How an FI code is treated by the wiring standard and by the landlord regulations, before and after 30 November 2026 How an FI code is treated, two rulebooks side by side Wiring standard BS 7671, used by the inspector Amendment 3 FI fails the report Amendment 4 FI no longer fails it Landlord regulations England, SI 2020/312 In force on 16 Nov 2026 Investigate in 28 days Draft, from 30 Nov 2026 No investigation duty The draft would drop the duty only for inspections completed on or after 30 November 2026, and only if it is made.
The wiring standard has already stopped treating an FI as a fail; the landlord regulations stop requiring the investigation only if the draft is made.
Until the amendment is made, treat an FI on a landlord's report as a 28-day job. That's what the regulations in force say today.

What happens if remedial work isn't done in time?

The council can act. Under the guidance, a council with reasonable grounds must serve a remedial notice. It can also arrange the work itself and recover the cost, or arrange urgent remedial action with the tenant's consent. It can also impose a financial penalty of up to £40,000. Our guide prices above let you budget the work before the deadline runs out.

When a tenant won't give access

If a tenant won't let the electrician in, the guidance says you aren't in breach just because you haven't taken them to court. Keep copies of every message about access. When access is agreed, call us on 07727 619854 to book the work.

Homeowners have no deadline, but C1 still means today

Owner-occupiers have no legal deadline for remedial work. Electrical Safety First suggests an inspection every 10 years for an owner-occupied home. Where dangerous conditions are found, it says remedial action is needed without delay. A C1 means acting straight away. The code guidance tells the inspector not to wait for the full report before saying so.

An EICR from us costs from £120 for a one-bedroom flat, including VAT, with any remedial work priced separately. Landlords can book the next inspection through our landlord EICR service in East London. Our guide to how often an EICR is needed sets out the intervals.

For EICRs and remedial work across London, see our EICR and electrical safety testing page or call 07727 619854.

Frequently asked questions

A new EICR isn't needed after remedial work: the official guidance accepts an Electrical Installation Certificate or a Minor Electrical Installation Works Certificate as proof. A satisfactory EICR also counts as proof.

We quote EICR remedial work separately once the report is written. Our guide prices start from £80 for replacing a socket or switch and from £400 for a new consumer unit, including VAT.

A council can ask a landlord for a copy of the EICR in writing, and the landlord must supply it within 7 days of the request.

A landlord whose tenant refuses access for EICR remedial work isn't in breach just because they haven't taken the tenant to court, the government's guidance says. Keep copies of every message about access as evidence of the steps you took.

Get a quote

Talk to DA Electrical London

Call, WhatsApp or send an enquiry and we'll come back to you with a fixed price.