Extractor fan installation cost in London (2026)

Published · 6 min read · By DA Electrical London
On this page
  1. Replacing a fan and fitting a new one are different jobs
  2. What changes the price of a replacement
  3. What decides the cost of a new fan
  4. How powerful the fan must be
  5. Bathroom zones decide which fan can go where
  6. Timer, humidistat and isolator
  7. When the work has to be notified
  8. Landlords: a dead fan becomes a damp problem

The short version

  • Replacing an extractor fan in London costs from £120, typically £120–£180 including VAT.
  • A fan where there was none is priced after a visit, because the wall, duct and power decide it.
  • A bathroom fan must extract at least 15 litres a second, and a kitchen fan 30 or 60.
  • Replacing a fan is never notifiable, but a new circuit or work around the bath or shower is.

Replacing an extractor fan in London costs from £120, typically £120–£180 including VAT, where the new fan uses the existing hole, duct and cable. Fitting a fan where there was none is a different job. The wall or ceiling, the duct route and the power supply decide it, so it is priced after a visit.

JobGuide price (VAT included)
Replacing an extractor fanfrom £120 (typically £120–£180)
Fan stopped working: finding the faultfrom £100
New fan where there was nonepriced after a visit

These are guide prices, not fixed quotes. A replacement price covers removing the old fan, fitting and wiring the new one, and testing it.

Replacing a fan and fitting a new one are different jobs

Most price confusion comes from treating these as one job. A like-for-like replacement reuses almost everything. A new installation builds the ventilation route from nothing.

ReplacementNew installation
HoleExistingNew hole or core drilled
DuctingExisting, checkedNew run to an outside wall or roof
PowerExisting supplyFrom a nearby circuit, or a new one
Building controlNever notifiableNotifiable in some cases, see below
Pricefrom £120After a visit
What a replacement extractor fan reuses, and what a new installation has to add Replacement from £120, VAT included Hole in the wall or ceiling: reused Duct to outside: reused Cable and supply: reused New fan: fitted and tested New installation priced after a visit New hole or core through a wall New duct run to the outside Power from a circuit, maybe new Isolator, timer and making good
A replacement reuses the hole, duct and cable, which is why it has a guide price. A new fan adds all three, so it is priced once someone has seen the room.

What changes the price of a replacement

A replacement usually lands inside the guide range. It moves towards the top when:

  • The new fan is a different size or fixing, so the opening needs adapting
  • The fan sits in a high ceiling or is only reachable from a loft
  • You are upgrading to a timer or humidistat model that needs an extra wire
  • There is no local isolator yet, and one has to be added
  • The duct turns out to be disconnected or crushed in the ceiling void

If the old fan simply stopped, the fan may not be the problem. A tripped circuit or a failed timer can look the same, which is why finding the fault starts from £100.

What decides the cost of a new fan

A new fan is priced after a visit because these vary so much between London homes:

  • The wall: solid brick takes a core drill, a stud wall does not
  • Above the ceiling: a loft gives easy access, a flat above does not
  • The duct run: its length and route to the outside
  • Internal bathrooms: many London flats have no outside wall, so the duct runs further
  • Power: taking a supply from the lighting circuit, or running a new circuit

To arrange a visit, see our electrician service in London or call 07727 619854.

How powerful the fan must be

The ventilation rules, Approved Document F, set minimum extract rates for fans that run when a room is in use:

RoomMinimum extract rate
Bathroom15 litres a second
Kitchen with a cooker hood venting outside30 litres a second
Kitchen with no hood, or one that does not vent outside60 litres a second
Utility room30 litres a second
Separate WC6 litres a second

Where the fan goes

An extract fan should sit as high as practical, within 400 mm of the ceiling, where warm, damp air collects. A cooker hood that only recirculates air does not count as kitchen ventilation on its own.

Air has to get in as well

A fan cannot pull air out of a sealed room. Internal doors need a gap underneath, the equivalent of a 10 mm undercut, so replacement air can reach the fan.

Bathroom zones decide which fan can go where

The wiring rules divide a bathroom into zones around the bath or shower. Any fan in zone 1 or zone 2 must be rated at least IPX4 against splashing water, and suitable for that position.

Bathroom zones seen from the side, with where a fan and its isolator can go up to 2.25 m high 0.6 m wide Zone 1 fan: IPX4 minimum Zone 2 IPX4 Zone 0: inside the bath Outside the zones switches go here Fan isolator
A fan above the bath sits in zone 1 and needs at least IPX4. Its isolator goes outside the zones, often just outside the door.

Every circuit in a bathroom also needs 30 mA RCD protection. Our guide to a fuse box that keeps tripping explains what an RCD does.

Timer, humidistat and isolator

The run-on timer

In a room with no openable window, the fan must keep running for at least 15 minutes after the room is left. That is why a fan wired to the light carries on after the light goes off.

The humidistat

A humidistat starts the fan when the air turns damp. Any automatic control like this should have a manual override, so you can still switch the fan on.

The isolator

A fan with a run-on timer needs a three-pole isolator, which cuts every wire feeding it, so it can be serviced safely. It goes outside the bathroom zones, often just outside the door.

When the work has to be notified

Replacing a fan on its existing cabling is not notifiable to building control. A new fan becomes notifiable if it needs a new circuit, or if it adds to or alters a circuit within the space around the bath or shower: up to 2.25 m high and 0.6 m out from its edge.

A registered electrician handles the notification and gives you a certificate for the work.

Landlords: a dead fan becomes a damp problem

Government guidance on damp and mould tells landlords to check that bathroom and kitchen fans work and vent outside. Serious damp and mould can be a hazard councils must act on. Awaab's Law currently applies to social housing only, but a working fan remains one of the simplest ways to keep a rented bathroom dry.

Frequently asked questions

Yes, if the fan is suitable for that position. Above a bath or shower is zone 1, where a fan must be rated at least IPX4 and approved by its maker for that zone. Adding to or altering a circuit in that space is notifiable, so use a registered electrician.

That is the run-on timer doing its job. In a room with no openable window, the fan should keep running for at least 15 minutes after the room is left, to clear the remaining moisture. A fan that never stops points to a faulty timer or humidistat.

The usual causes are dust clogging the intake, a duct that has come loose or been crushed, a fan too weak for the room, or no gap under the door to let air in. Cleaning to the maker's instructions fixes the first; the others need the fan and duct checked.

Safety guidance is to use a registered electrician. Bathroom circuits need RCD protection, the fan must suit its zone, and the isolator has to be wired correctly. A registered electrician tests the work and certifies it.